SN EN 60601-1-3-1994  医用电气设备 - 第1部分:安全通用要求 - 3.并列标准:一般要求的辐射防护X射线诊断设备

标准编号:SN EN 60601-1-3-1994
分享到:

中文标准名称:医用电气设备 - 第1部分:安全通用要求 - 3.并列标准:一般要求的辐射防护X射线诊断设备
英文标准名称:Medical Electrical Equipment - Part 1: General Requirements For Safety - 3. Collateral Standard: General Requirements For Radiation Protection In Diagnostic X-ray Equipment
标准状态:现行有效
采用国际标准编号:UNE EN 60601-1-3-1996 Identical
SS EN 60601-1-3 Ed. 1 (1995) Identical
EN 60601-1-3-1
语言:德语版,英语版, 中文版, 英文版
标准类别:瑞士标准化协会SNV
中国标准文献分类法(中标分类CCS):
中国标准文献分类法(中标分类CCS):医药卫生技术 >> 医疗设备 >> 射线照相设备
标准目录:Cooperating organizations
National foreword
Foreword
Introduction
SECTION 1: GENERAL
1.       Scope, object and relationship to other 
         standards
1.201    Scope
1.202    Object
1.203    Relationship to other standards
1.203.1  IEC 601-1
1.203.2  Particular Standards
1.203.3  Superseded IEC Standards
1.203.4  Normative references
1.203.5  Other related IEC Standards
2.       Terminology and definitions
2.201    Defined terms
2.202    Qualifying conditions for defined terms
2.202.1  Boundary and dimensions of the X-RAY FIELD
2.202.2  Operating Conditions for NOMINAL X-RAY TUBE 
         VOLTAGE
2.202.3  Effective IMAGE RECEPTION AREA
2.202.4  The IMAGE RECEPTOR PLANE in X-RAY IMAGE 
         INTENSIFIER
         TUBES
2.202.5  Modes of operation with CONTINUED DISPLAY
2.203    Composition of reference materials
2.204    Degrees of requirement and miscellaneous terms
2.205    RADIATION QUANTITIES and units
4.       General requirements for tests
4.201    Compliance
4.201.1  Statement of compliance
6.       Identification, marking and documents
6.1      Marking on the outside of EQUIPMENT or 
         EQUIPMENT 
         parts
6.1.201  Marking requirements in subclauses
6.1.202  General requirements
6.8      ACCOMPANYING DOCUMENTS
6.8.201  Reference in subclauses
6.8.202  General requirements
SECTION 5: PROTECTION AGAINST HAZARDS FROM UNWANTED OR 
           EXCESSIVE RADIATION
29.      X-RADIATION
29.201   RADIATION QUALITY
29.201.1 Limitation of operating voltage range in dental 
         applications
29.201.2 HALF-VALUE LAYERS in X-RAY EQUIPMENT
29.201.3 FILTRATION in X-RAY TUBE ASSEMBLIES
29.201.4 FILTRATION in X-RAY SOURCE ASSEMBLIES
29.201.5 TOTAL FILTRATION in X-RAY EQUIPMENT
29.201.6 Indication of FILTER properties
29.201.7 Test for FILTRATION by irremovable materials
29.201.8 Test for ADDED FILTERS and materials
29.201.9 Test for HALF-VALUE LAYER
29.202   Limitation and indication of the extent of the 
         X-RAY BEAM
29.202.1 Enclosure of X-RAY TUBES
29.202.2 Limiting DIAPHRAGM in X-RAY TUBE ASSEMBLIES
29.202.3 Confinement of EXTRA-FOCAL RADIATION
29.202.4 Methods of beam limitation in X-RAY EQUIPMENT
29.202.5 Indication on the EQUIPMENT
29.202.6 Indication in the INSTRUCTIONS FOR USE
29.202.7 Indication by LIGHT FIELD-INDICATOR
28.202.8 Accuracy of marked and written indications
29.202.9 Accuracy of indication with a LIGHT 
         FIELD-INDICATOR
29.203   Relationship between X-RAY FIELD and IMAGE 
         RECEPTION AREA
29.203.1 Positioning of the REFERENCE AXIS
29.203.2 FOCAL SPOT TO IMAGE RECEPTOR DISTANCE
29.203.3 Interception of the X-RAY BEAM in RADIOSCOPY
29.203.4 Correspondence between X-RAY FIELD and IMAGE
         RECEPTION AREA
29.204   LEAKAGE RADIATION
29.204.1 Mounting of X-RAY SOURCE ASSEMBLIES
29.204.2 Statement of reference LOADING conditions
29.204.3 LEAKAGE RADIATION in the LOADING STATE
29.204.4 LEAKAGE RADIATION during LOADING for voltage
         adjustment
29.204.5 LEAKAGE RADIATION when not in the LOADING STATE
29.205   FOCAL SPOT TO SKIN DISTANCE
29.205   X-RAY EQUIPMENT for RADIOGRAPHY
29.205.3 Information in the ACCOMPANYING DOCUMENTS
29.206   ATTENUATION of the X-RAY BEAM
29.206.1 ATTENUATION by items in the X-RAY BEAM
29.206.2 Information in the ACCOMPANYING DOCUMENTS
29.206.3 Test for ATTENUATION EQUIVALENT
29.207   PRIMARY PROTECTIVE SHIELDING
29.207.1 Requirements
29.207.2 Test for ATTENUATION of RESIDUAL RADIATION
29.207.3 Test for ATTENUATION EQUIVALENT
29.208   Protection against STRAY RADIATION
29.208.1 Protection by distance
29.208.2 Control from a PROTECTED AREA
29.208.3 Designated SIGNIFICANT ZONES OF OCCUPANCY
29.208.4 SIGNIFICANT ZONES OF OCCUPANCY with limited 
         STRAY RADIATION
29.208.5 Handgrips and control devices
29.208.6 Test for STRAY RADIATION
Annexes
AAA - Recommendations for the provision of information
      concerning STRAY RADIATION
BBB - Index of defined terms
CCC - Normative references to ACCOMPANYING DOCUMENTS, 
      INSTRUCTIONS FOR USE and ASSEMBLING INSTRUCTIONS
ZA (normative) Other international publications quoted
               in this standard with the references of
               the relevant European publications
ZB (informative) Other international publications quoted
                 in this standard with the references of 
                 the relevant European publications
Tables
201.   Subclauses containing requirements for marking
202.   Subclauses requiring statements in ACCOMPANYING
       DOCUMENTS
203.   Voltage restrictions in dental X-RAY EQUIPMENT
204.   HALF-VALUE LAYERS in X-RAY EQUIPMENT
205.   Minimum FOCAL SPOT TO SKIN DISTANCES
206.   ATTENUATION EQUIVALENT of items in the X-RAY BEAM
207.   Parameters for testing ATTENUATION EQUIVALENT
208a.  Application categories
208b.  Requirements for PRIMARY PROTECTIVE SHIELDING
209.   STRAY RADIATION IN SIGNIFICANT ZONES OF OCCUPANCY
Figures
201.   Zone of EXTRA-FOCAL RADIATION
202.   Discrepancies in visual indication of the X-RAY
       FIELD
203.   Discrepancies in covering the IMAGE RECEPTION 
       AREA
204.   Testing for STRAY RADIATION (undertable tube with
       X-RAY BEAM horizontal)
205.   Testing for STRAY RADIATION (undertable tube with
       X-RAY BEAM vertical)
206.   Testing for STRAY RADIATION (overtable tube with
       X-RAY BEAM horizontal)
207.   Testing for STRAY RADIATION (overtable tube with
       X-RAY BEAM vertical)
208.   Example of presentation of data on STRAY 
       RADIATION
标准简介:ALSO NUMBERED AS BS 5724- SECTION 1.3- 1995 Establishes general requirements for protection against ionizing radiation in medical diagnostic x-ray equipment. Also gives tables, diagrams, annexes, and terminology and definitions.
文件格式:纸质版或者PDF电子版(用Acrobat Reader打开)或Word版本doc格式
PDF格式 SN EN 60601-1-3-1994 医用电气设备 - 第1部分:安全通用要求 - 3.并列标准:一般要求的辐射防护X射线诊断设备
 免费下载 Word格式 SN EN 60601-1-3-1994 医用电气设备 - 第1部分:安全通用要求 - 3.并列标准:一般要求的辐射防护X射线诊断设备
 免费下载免费标准下载
文件大小:817 KB
添加时间:2015/01/09
 